A ceiling-mounted dehumidifier preserves usable floor space by placing the equipment overhead.

Ducted installation: airflow and external static pressure

Every RYDZ model can be installed above the ceiling and connected to supply and return ducts, so dry air reaches the space while the unit stays out of the way. Size the ductwork so its pressure loss stays within the unit's available external static pressure at the required airflow. The table below lists both for each model.

ModelRemoval (L/day)Airflow (m³/h)External static pressure (Pa)
RYDZ-26DM2626040-60
RYDZ-58DM5855040-60
RYDZ-90DM90100050-80
RYDZ-138DM138130050-80
RYDZ-7S1681800100
RYDZ-10S2402500100
RYDZ-12S2883000120
RYDZ-22S4805600150
RYDZ-30S7207400200
RYDZ-40S96010000200

MODEL SELECTION

Ceiling-mounted and ducted model range

Compare all ten RYDZ models at the stated rating condition. Follow a model link for its full specifications.

Rated data by model. Scroll horizontally to review all columns.
ModelL/dayPPD (converted)Rating conditionAirflowExternal pressurePower supply (V / phase / Hz)Machine dimensionsNet weightDrainage
RYDZ-26DM 2655 30°C/80% RH 260 m³/h40-60 Pa220 V / 1-phase / 50 Hz 685*310*211 mm16 kgExternal Hose Drainage
RYDZ-58DM 58123 30°C/80% RH 550 m³/h40-60 Pa220 V / 1-phase / 50 Hz 830*490*370 mm35 kgExternal Hose Drainage
RYDZ-90DM 90190 30°C/80% RH 1000 m³/h50-80 Pa220 V / 1-phase / 50 Hz 900*570*450 mm49 kgExternal Hose Drainage
RYDZ-138DM 138292 30°C/80% RH 1300 m³/h50-80 Pa220 V / 1-phase / 50 Hz 900*570*450 mm53 kgExternal Hose Drainage
RYDZ-7S 168355 30°C/80% RH 1800 m³/h100 Pa380 V / 3-phase / 50 Hz 1050*700*700 mm100 kgExternal Hose Drainage
RYDZ-10S 240507 30°C/80% RH 2500 m³/h100 Pa380 V / 3-phase / 50 Hz 1050*700*700 mm110 kgExternal Hose Drainage
RYDZ-12S 288609 30°C/80% RH 3000 m³/h120 Pa380 V / 3-phase / 50 Hz 1100*900*700 mm126 kgExternal Hose Drainage
RYDZ-22S 4801014 30°C/80% RH 5600 m³/h150 Pa380 V / 3-phase / 50 Hz 1100*1280*700 mm210 kgExternal Hose Drainage
RYDZ-30S 7201521 30°C/80% RH 7400 m³/h200 Pa380 V / 3-phase / 50 Hz 1510*1500*800 mm330 kgExternal Hose Drainage
RYDZ-40S 9602028 30°C/80% RH 10000 m³/h200 Pa380 V / 3-phase / 50 Hz 1510*1500*800 mm375 kgExternal Hose Drainage

Ratings are measured at the stated conditions. Send us your site conditions and we will confirm the right model.

PPD means US pints per day: L/day × 2.113, rounded to the nearest whole pint. Unit conversion is not an AHAM/DOE test rating.

Conversion, rating and installation notes

L/day retains the original rated precision. Ratings at different conditions cannot be ranked directly. Confirm capacity at the actual inlet temperature and humidity; operating range is a separate specification.

AIR-PATH OPTIONS

Direct-air or ducted installation

Ceiling mounting describes the equipment position; ducting describes its air path. A ceiling-mounted unit may need a direct-air or ducted layout, subject to model and installation review.

Yakeclimate equipment assembly
Yakeclimate equipment assembly
Ceiling Dehumidifier
01

Ceiling / direct air

Room return air → unit → supply air to the room. Preserve floor space and provide clear intake, discharge, drainage and service access.

Ceiling Dehumidifier
02

Ceiling / ducted air

Return path → unit → supply duct → served zone. Submit both air paths, duct sizes, bends, dampers and filter pressure losses.

Floor-standing RYCF models
03

Floor-standing alternative

Consider a floor-standing model where overhead support or service access is impractical. Check the moisture load and the floor-level air circulation route.

AIRFLOW & PRESSURE

Match airflow and external pressure to the duct path

Use the model table to compare airflow and external pressure together. The RYDZ-26DM and 58DM list 40–60 Pa; 90DM and 138DM list 50–80 Pa. Larger models list 100–200 Pa. These values do not specify an allowable duct length. Submit supply and return layouts and their pressure losses for review; an existing HVAC connection also needs airflow and control-interlock checks.

RYDZ-26DM / 58DM
40–60 Pa
RYDZ-90DM / 138DM
50–80 Pa
Larger RYDZ models
100–200 Pa

INSTALLATION REVIEW

Ceiling clearance, drainage and service access

Use the dimensions, net weight and drainage entries below to prepare the installation review. Confirm structural support, access for filter and equipment service, and the drain route with the installation designer. Required clearances and fixings depend on the selected model and structure.

Yakeclimate manufacturing detail
Yakeclimate manufacturing detail

RATING & DUTY

Select capacity at your operating temperature

The RYDZ capacity ratings use 30°C/80% RH. For a greenhouse or grow room, provide the colder night-time condition as well as daytime values. State moisture load, target temperature/RH and operating hours; floor area alone cannot establish the required capacity.

RYDZ capacity rating condition
30°C / 80% RH
Submit both project conditions
Day + night

FACTORY TESTING

Factory testing and model-specific records

Our performance laboratory supports equipment testing. Ask for the model-specific test conditions and available records.

Explore our manufacturing facilities
Yakeclimate performance laboratory equipment
Performance testing facilities; results for a specific model require its corresponding test records.

PROJECT REVIEW

Send your project selection inputs

Include the following information for a model and configuration review.

Need a custom configuration?
  1. 01

    Application, entering-air temperature/RH, target condition, moisture load and operating hours

  2. 02

    Ceiling clearance, support conditions, service access and drain location

  3. 03

    Supply/return drawings, duct sizes, bends, dampers and filter pressure losses

  4. 04

    Site voltage, phase and frequency; control interfaces, quantity and destination country

TECHNOLOGY COMPARISON

Refrigerant versus desiccant rotor technology

The Industrial Ceiling Dehumidifier on this page is part of the Industrial Ceiling Dehumidifier range; compare the rated values in each model specification table with the working principles below.

Technology route How it works Typical applications
Refrigerant dehumidification Cools air below dew point to condense and separate water vapor Conventional dehumidification duty in commercial and industrial spaces
Desiccant rotor dehumidification Adsorbs moisture onto a rotating wheel and regenerates it continuously Lower-temperature or lower-humidity targets in storage and process environments
Ultrasonic humidification Adds fine water mist to raise or compensate relative humidity Humidity compensation in agriculture and process areas

Application fit

Where this product can be evaluated

Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.

  1. 01Greenhouses
  2. 02workshops
  3. 03storage rooms
  4. 04pools
  5. 05large humidity-control spaces

SELECTION STEPS

How to select the right configuration

  1. Step 1 — define the operating conditions. Record the temperature range, current and target relative humidity, moisture load, and the volume of the room or enclosure to be protected.
  2. Step 2 — confirm the site constraints. Check the available power supply, drainage method, airflow or static-pressure requirement, and installation space; for ceiling, cabinet, or portable mounting confirm the fixing method and service access.
  3. Step 3 — review the rated data and confirm the configuration. Compare the rated capacity in L/day and the surrounding specification values in the table against the recorded conditions, then confirm the configuration with Yakeclimate before ordering.
Product definition and technical notes

What is a ceiling-mounted dehumidifier?

A ceiling-mounted dehumidifier preserves usable floor space by placing the equipment overhead. Direct-air and ducted layouts must be reviewed against the selected model's airflow, external pressure, drainage, structural support and service access.

How this product family supports a project

Ceiling dehumidification products for higher-capacity commercial and industrial applications.

  • Ceiling-mounted configurations for projects that need to preserve floor space.
  • Multiple capacities available for different room volumes and moisture loads.
  • Airflow, external pressure, drainage, and power supply can be reviewed during selection.
  • Designed for integration into larger commercial and industrial spaces.

Company record behind this product

Since 2010, Yakeclimate has supplied customers in 50+ countries and regions, and holds 46+ patents supporting product and application development alongside a national-level laboratory. The specification values on this page are published from the current product record and reviewed against project conditions before quotation.

Need a custom configuration?

View all product families

FAQ

Frequently Asked Questions

Is the Industrial Ceiling Dehumidifier capacity rating based on standard testing conditions?

Rated capacity is published under the named condition in the specification table (for example 30°C/80% RH, in L/day). Actual moisture removal depends on operating temperature, humidity, airflow, and installation conditions.

Which applications can the Industrial Ceiling Dehumidifier support?

The applications listed on this page are evaluation starting points. Final suitability depends on the moisture load, temperature, airflow, and installation limits of the project.

How does Yakeclimate support project configuration?

See our engineering page for application-specific equipment development and project configuration review.

Can a commercial dehumidifier be ducted?

A ducted layout must match the selected model's airflow and external pressure. Send the supply and return paths, fittings and pressure losses for review before confirming a connection.

Which ceiling-mounted dehumidifier should I choose?

Start with moisture load and operating temperature/RH, then check external pressure, dimensions, weight, drainage, power and service access against the model tables.

Is there a small ducted dehumidifier in the range?

RYDZ-26DM and RYDZ-58DM are candidates at 26 and 58 L/day respectively at 30°C/80% RH, with 40–60 Pa external pressure. Check dimensions and the proposed duct path on the model pages before selection.

How should a dehumidifier be hung from the ceiling?

The installation designer must check the selected model's net weight, structural support, drainage and service access. Fixings and minimum clearances need model-specific installation confirmation.

Can I connect it to an existing HVAC system?

Submit the HVAC drawings, air paths and operating sequence for review. Available external pressure does not by itself confirm compatibility with every duct circuit or control arrangement.

Project support

Confirm the right configuration for your operating conditions.

Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.

Send project requirements