Product family
Ceiling-Mounted and Ducted Dehumidifiers
Ceiling dehumidification products for higher-capacity commercial and industrial applications.
Compare ceiling-mounted dehumidifiers for ducted or direct-air project layouts. Check rated capacity, airflow and external pressure before choosing a model.

A ceiling-mounted dehumidifier preserves usable floor space by placing the equipment overhead.
Ducted installation: airflow and external static pressure
Every RYDZ model can be installed above the ceiling and connected to supply and return ducts, so dry air reaches the space while the unit stays out of the way. Size the ductwork so its pressure loss stays within the unit's available external static pressure at the required airflow. The table below lists both for each model.
MODEL SELECTION
Ceiling-mounted and ducted model range
Compare all ten RYDZ models at the stated rating condition. Follow a model link for its full specifications.
| Model | L/day | PPD (converted) | Rating condition | Airflow | External pressure | Power supply (V / phase / Hz) | Machine dimensions | Net weight | Drainage |
|---|---|---|---|---|---|---|---|---|---|
| RYDZ-26DM | 26 | 55 | 30°C/80% RH | 260 m³/h | 40-60 Pa | 220 V / 1-phase / 50 Hz | 685*310*211 mm | 16 kg | External Hose Drainage |
| RYDZ-58DM | 58 | 123 | 30°C/80% RH | 550 m³/h | 40-60 Pa | 220 V / 1-phase / 50 Hz | 830*490*370 mm | 35 kg | External Hose Drainage |
| RYDZ-90DM | 90 | 190 | 30°C/80% RH | 1000 m³/h | 50-80 Pa | 220 V / 1-phase / 50 Hz | 900*570*450 mm | 49 kg | External Hose Drainage |
| RYDZ-138DM | 138 | 292 | 30°C/80% RH | 1300 m³/h | 50-80 Pa | 220 V / 1-phase / 50 Hz | 900*570*450 mm | 53 kg | External Hose Drainage |
| RYDZ-7S | 168 | 355 | 30°C/80% RH | 1800 m³/h | 100 Pa | 380 V / 3-phase / 50 Hz | 1050*700*700 mm | 100 kg | External Hose Drainage |
| RYDZ-10S | 240 | 507 | 30°C/80% RH | 2500 m³/h | 100 Pa | 380 V / 3-phase / 50 Hz | 1050*700*700 mm | 110 kg | External Hose Drainage |
| RYDZ-12S | 288 | 609 | 30°C/80% RH | 3000 m³/h | 120 Pa | 380 V / 3-phase / 50 Hz | 1100*900*700 mm | 126 kg | External Hose Drainage |
| RYDZ-22S | 480 | 1014 | 30°C/80% RH | 5600 m³/h | 150 Pa | 380 V / 3-phase / 50 Hz | 1100*1280*700 mm | 210 kg | External Hose Drainage |
| RYDZ-30S | 720 | 1521 | 30°C/80% RH | 7400 m³/h | 200 Pa | 380 V / 3-phase / 50 Hz | 1510*1500*800 mm | 330 kg | External Hose Drainage |
| RYDZ-40S | 960 | 2028 | 30°C/80% RH | 10000 m³/h | 200 Pa | 380 V / 3-phase / 50 Hz | 1510*1500*800 mm | 375 kg | External Hose Drainage |
PPD means US pints per day: L/day × 2.113, rounded to the nearest whole pint. Unit conversion is not an AHAM/DOE test rating.
Conversion, rating and installation notes
L/day retains the original rated precision. Ratings at different conditions cannot be ranked directly. Confirm capacity at the actual inlet temperature and humidity; operating range is a separate specification.
AIR-PATH OPTIONS
Direct-air or ducted installation
Ceiling mounting describes the equipment position; ducting describes its air path. A ceiling-mounted unit may need a direct-air or ducted layout, subject to model and installation review.

Ceiling / direct air
Room return air → unit → supply air to the room. Preserve floor space and provide clear intake, discharge, drainage and service access.
Ceiling / ducted air
Return path → unit → supply duct → served zone. Submit both air paths, duct sizes, bends, dampers and filter pressure losses.
Floor-standing alternative
Consider a floor-standing model where overhead support or service access is impractical. Check the moisture load and the floor-level air circulation route.
AIRFLOW & PRESSURE
Match airflow and external pressure to the duct path
Use the model table to compare airflow and external pressure together. The RYDZ-26DM and 58DM list 40–60 Pa; 90DM and 138DM list 50–80 Pa. Larger models list 100–200 Pa. These values do not specify an allowable duct length. Submit supply and return layouts and their pressure losses for review; an existing HVAC connection also needs airflow and control-interlock checks.
- RYDZ-26DM / 58DM
- 40–60 Pa
- RYDZ-90DM / 138DM
- 50–80 Pa
- Larger RYDZ models
- 100–200 Pa
INSTALLATION REVIEW
Ceiling clearance, drainage and service access
Use the dimensions, net weight and drainage entries below to prepare the installation review. Confirm structural support, access for filter and equipment service, and the drain route with the installation designer. Required clearances and fixings depend on the selected model and structure.

RATING & DUTY
Select capacity at your operating temperature
The RYDZ capacity ratings use 30°C/80% RH. For a greenhouse or grow room, provide the colder night-time condition as well as daytime values. State moisture load, target temperature/RH and operating hours; floor area alone cannot establish the required capacity.
- RYDZ capacity rating condition
- 30°C / 80% RH
- Submit both project conditions
- Day + night
FACTORY TESTING
Factory testing and model-specific records
Our performance laboratory supports equipment testing. Ask for the model-specific test conditions and available records.
Explore our manufacturing facilities
PROJECT REVIEW
Send your project selection inputs
Include the following information for a model and configuration review.
Need a custom configuration?- 01
Application, entering-air temperature/RH, target condition, moisture load and operating hours
- 02
Ceiling clearance, support conditions, service access and drain location
- 03
Supply/return drawings, duct sizes, bends, dampers and filter pressure losses
- 04
Site voltage, phase and frequency; control interfaces, quantity and destination country
FURTHER READING
Selection and application resources
TECHNOLOGY COMPARISON
Refrigerant versus desiccant rotor technology
The Industrial Ceiling Dehumidifier on this page is part of the Industrial Ceiling Dehumidifier range; compare the rated values in each model specification table with the working principles below.
| Technology route | How it works | Typical applications |
|---|---|---|
| Refrigerant dehumidification | Cools air below dew point to condense and separate water vapor | Conventional dehumidification duty in commercial and industrial spaces |
| Desiccant rotor dehumidification | Adsorbs moisture onto a rotating wheel and regenerates it continuously | Lower-temperature or lower-humidity targets in storage and process environments |
| Ultrasonic humidification | Adds fine water mist to raise or compensate relative humidity | Humidity compensation in agriculture and process areas |
Application fit
Where this product can be evaluated
Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.
- 01Greenhouses
- 02workshops
- 03storage rooms
- 04pools
- 05large humidity-control spaces
Available models
Model range
SELECTION STEPS
How to select the right configuration
- Step 1 — define the operating conditions. Record the temperature range, current and target relative humidity, moisture load, and the volume of the room or enclosure to be protected.
- Step 2 — confirm the site constraints. Check the available power supply, drainage method, airflow or static-pressure requirement, and installation space; for ceiling, cabinet, or portable mounting confirm the fixing method and service access.
- Step 3 — review the rated data and confirm the configuration. Compare the rated capacity in L/day and the surrounding specification values in the table against the recorded conditions, then confirm the configuration with Yakeclimate before ordering.
Product definition and technical notes
What is a ceiling-mounted dehumidifier?
A ceiling-mounted dehumidifier preserves usable floor space by placing the equipment overhead. Direct-air and ducted layouts must be reviewed against the selected model's airflow, external pressure, drainage, structural support and service access.
How this product family supports a project
Ceiling dehumidification products for higher-capacity commercial and industrial applications.
- Ceiling-mounted configurations for projects that need to preserve floor space.
- Multiple capacities available for different room volumes and moisture loads.
- Airflow, external pressure, drainage, and power supply can be reviewed during selection.
- Designed for integration into larger commercial and industrial spaces.
Company record behind this product
Since 2010, Yakeclimate has supplied customers in 50+ countries and regions, and holds 46+ patents supporting product and application development alongside a national-level laboratory. The specification values on this page are published from the current product record and reviewed against project conditions before quotation.
Need a custom configuration?FAQ
Frequently Asked Questions
Is the Industrial Ceiling Dehumidifier capacity rating based on standard testing conditions?
Rated capacity is published under the named condition in the specification table (for example 30°C/80% RH, in L/day). Actual moisture removal depends on operating temperature, humidity, airflow, and installation conditions.
Which applications can the Industrial Ceiling Dehumidifier support?
The applications listed on this page are evaluation starting points. Final suitability depends on the moisture load, temperature, airflow, and installation limits of the project.
How does Yakeclimate support project configuration?
Can a commercial dehumidifier be ducted?
A ducted layout must match the selected model's airflow and external pressure. Send the supply and return paths, fittings and pressure losses for review before confirming a connection.
Which ceiling-mounted dehumidifier should I choose?
Start with moisture load and operating temperature/RH, then check external pressure, dimensions, weight, drainage, power and service access against the model tables.
Is there a small ducted dehumidifier in the range?
RYDZ-26DM and RYDZ-58DM are candidates at 26 and 58 L/day respectively at 30°C/80% RH, with 40–60 Pa external pressure. Check dimensions and the proposed duct path on the model pages before selection.
How should a dehumidifier be hung from the ceiling?
The installation designer must check the selected model's net weight, structural support, drainage and service access. Fixings and minimum clearances need model-specific installation confirmation.
Can I connect it to an existing HVAC system?
Submit the HVAC drawings, air paths and operating sequence for review. Available external pressure does not by itself confirm compatibility with every duct circuit or control arrangement.
Project support
Confirm the right configuration for your operating conditions.
Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.
Send project requirements