Ceiling Dehumidifier
RYDZ-26DM
Ceiling Dehumidifier – 26L per 24hr refrigerant dehumidifier
RYDZ-26DM is a ceiling dehumidifier with a rated output of 26 l/24h and an airflow reference of 260 m³/h, intended for commercial and industrial spaces where ceiling installation preserves floor area. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, drainage, power supply, and installation conditions.
- Dehumidification Capacity
- 26 l/24h
- Air Volume
- 260 m³/h
- Power Supply
- 220/1ph/50 V/Hz
- Applicable Temperature
- 5-38 °C
Product selection should be confirmed against temperature, target humidity, airflow, drainage, power supply, and installation conditions.
DEFINITION
What is an industrial dehumidifier?
An industrial dehumidifier is a humidity-control device that removes water vapor from ambient or process air and holds relative humidity at a defined operating level. Industrial models are specified against the operating temperature, target humidity, airflow, drainage, and power supply of a project rather than by floor area alone.
RYDZ-26DM is a Ceiling Dehumidifier unit with a published rated capacity of 26 l/24h on this page.
Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications, with a focus on agriculture and energy projects.
Product overview
What RYDZ-26DM is designed to do
RYDZ-26DM is a ceiling dehumidifier with a rated output of 26 l/24h and an airflow reference of 260 m³/h, intended for commercial and industrial spaces where ceiling installation preserves floor area. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, drainage, power supply, and installation conditions.
Automatic dehumidification mode
High efficiency dehumidification capacity with branded compressor
Intelligent controller panel & remote control
Strong copper motor with high air volume
Automatic drainage function
High durability metal shell
Timer on/off function
Ceiling installation saves floor space
Product video
See RYDZ-26DM in detail
Review the equipment form, exterior layout, and product details in this short video before confirming selection and integration requirements for your project.
Watch on YouTube This video presents the equipment itself. Final model selection and configuration still depend on operating conditions and project requirements.Technical data
Product specifications
Values below are retained from the current product record. Final configuration should be confirmed in the project quotation.
| Specification | Unit | RYDZ-26DM |
|---|---|---|
| Power Supply | V/Hz | 220/1ph/50 |
| Dehumidification Capacity(30°C/80% RH) | l/24h | 26 |
| Maximum Power | kW | 0.2 |
| Input Current | A | 2.5 |
| Air Volume | m³/h | 260 |
| External Pressure | Pa | 40-60 |
| Filtration Device | — | Dual-layer Nylon Filter |
| Applicable Temperature | °C | 5-38 |
| Drainage Method | — | External Hose Drainage |
| Control Method | — | 86*86 Box Controller |
| Refrigerant | — | R134a |
| Noise Level | dB(A) | ≤45 |
| Return Air Outlet Diameter | mm | 150 |
| Supply Air Outlet Diameter | mm | 100 |
| Machine Dimensions | mm | 685*310*211 |
| Net Weight | kg | 16 |
TECHNOLOGY COMPARISON
Refrigerant versus desiccant rotor technology
The RYDZ-26DM on this page is a Ceiling Dehumidifier unit; compare its published ratings in the specification table with the working principles below.
| Technology route | How it works | Typical applications |
|---|---|---|
| Refrigerant dehumidification | Cools air below dew point to condense and separate water vapor | Conventional dehumidification duty in commercial and industrial spaces |
| Desiccant rotor dehumidification | Adsorbs moisture onto a rotating wheel and regenerates it continuously | Lower-temperature or lower-humidity targets in storage and process environments |
| Ultrasonic humidification | Adds fine water mist to raise or compensate relative humidity | Humidity compensation in agriculture and process areas |
Application fit
Where this product can be evaluated
Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.
- 01Agriculture
- 02Buildings and commercial spaces
- 03Data centres and telecoms
- 04Food and beverage
- 05General industry and production
- 06Leisure and recreation
- 07Museum and gallery preservation
- 08Pharmaceutical and scientific
- 09Storage, preservation and archives
Compare the range
Other Ceiling Dehumidifier models
SELECTION STEPS
How to select the right configuration
- Step 1 — define the operating conditions. Record the temperature range, current and target relative humidity, moisture load, and the volume of the room or enclosure to be protected.
- Step 2 — confirm the site constraints. Check the available power supply, drainage method, airflow or static-pressure requirement, and installation space; for ceiling, cabinet, or portable mounting confirm the fixing method and service access.
- Step 3 — review the rated data and confirm the configuration. Compare the rated capacity in l/24h and the surrounding specification values in the table against the recorded conditions, then confirm the configuration with Yakeclimate before ordering.
FAQ
Frequently Asked Questions
Is the RYDZ-26DM capacity rating based on standard testing conditions?
Rated capacity is published under the named condition in the specification table (for example 30°C/80% RH, in l/24h). Actual moisture removal depends on operating temperature, humidity, airflow, and installation conditions.
Which applications can the RYDZ-26DM support?
The applications listed on this page are evaluation starting points. Final suitability depends on the moisture load, temperature, airflow, and installation limits of the project.
How does Yakeclimate support project configuration?
We co-develop application-specific dehumidification equipment around the operating conditions, interfaces, and integration requirements of the wider project or system.
Project support
Confirm the right configuration for your operating conditions.
Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.
Send project requirements