Product family
Industrial Dehumidifier
Industrial refrigerant dehumidifiers for manufacturing spaces, storage rooms, workshops, and project-based humidity control.
Compare portable and floor-standing refrigerant dehumidifiers for 50Hz markets and project procurement, with rated capacity, drainage and power data for selection.

Product selection should be confirmed against temperature, target humidity, airflow, drainage, power supply, and installation conditions.
DEFINITION
What is an industrial dehumidifier?
Industrial refrigerant dehumidifiers remove moisture from air in manufacturing spaces, warehouses and storage rooms. The RYCM portable and RYCF floor-standing ranges are selected against moisture load, operating temperature/RH, airflow, drainage and the site's power supply.
Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications, with a focus on agriculture and energy projects.
Product overview
How this product family supports a project
Industrial refrigerant dehumidifiers for manufacturing spaces, storage rooms, workshops, and project-based humidity control.
Floor-standing and portable configurations for different site layouts.
Model selection based on moisture load, temperature, airflow, and drainage conditions.
Project quotation and configuration support for industrial environments.
Continuous drainage options for long operating cycles.
MODEL SELECTION
Commercial and industrial model range
The RYCM and RYCF ranges cover 60–960 L/day at 30°C/80% RH. Select by actual moisture load and installation conditions, then confirm the model and electrical configuration for your destination.
| Model | L/day | PPD (converted) | Rating condition | Airflow | Power supply (V / phase / Hz) | Maximum power |
|---|---|---|---|---|---|---|
| RYCM-60C | 60 | 127 | 30°C/80% RH | 480 m³/h | 220/1ph/50 | Max Power: 0.78 kW |
| RYCM-90C | 90 | 190 | 30°C/80% RH | 1000 m³/h | 220/1ph/50 | Max Power: 1.35 kW |
| RYCM-138C | 138 | 292 | 30°C/80% RH | 1300 m³/h | 220/1ph/50 | Max Power: 1.68 kW |
| RYCF-10S | 240 | 507 | 30°C/80% RH | 2800 m³/h | 380/3ph/50 | Max Power: 4.25 kW |
| RYCF-12S | 288 | 609 | 30°C/80% RH | 3000 m³/h | 380/3ph/50 | Max Power: 4.65 kW |
| RYCF-16S | 384 | 811 | 30°C/80% RH | 5000 m³/h | 380/3ph/50 | Max Power: 6.3 kW |
| RYCF-22S | 480 | 1014 | 30°C/80% RH | 5600 m³/h | 380/3ph/50 | Max Power: 8.4 kW |
| RYCF-30S | 720 | 1521 | 30°C/80% RH | 7400 m³/h | 380/3ph/50 | Max Power: 12 kW |
| RYCF-40S | 960 | 2028 | 30°C/80% RH | 10000 m³/h | 380/3ph/50 | Max Power: 15 kW |
PPD means US pints per day, converted as L/day × 2.113 and rounded to the nearest whole number. L/day retains the original rated precision. Conversion is not an AHAM/DOE test result; ratings at different conditions cannot be ranked directly.
INSTALLATION FORMAT
Portable or floor-standing: choose the installation format
Use capacity and the air path together when deciding between mobile and fixed-position equipment. The listed capacities share the 30°C/80% RH rating condition; room area alone cannot determine the number of units.

Portable RYCM models
Compare RYCM-60C, RYCM-90C and RYCM-138C for mobile or zoned duty: 60, 90 and 138 L/day at 30°C/80% RH. Check moving access and drainage at every intended location. Use the net weights below to plan doorways, thresholds and handling equipment. Before moving, follow the model manual for shutdown and draining retained water.
Floor-standing RYCF models
Compare the six RYCF models for a fixed area and larger moisture load, from 240 to 960 L/day at 30°C/80% RH. Check three-phase power, air circulation and an external drain. Confirm the delivery route and handling method against net weight and dimensions. Verify gravity drainage or a pump arrangement for the selected model; an external hose does not establish that a pump is supplied.
Overhead or dry-air requirements
If floor space is constrained, review the ceiling-mounted range. For a lower temperature or lower humidity target, compare the desiccant range using the same project conditions.
CAPACITY CONVERSION
Compare L/day and PPD at the same rating condition
138 L/day converts to 291.594 US pints/day, shown as 292 PPD. It is not a 300 PPD rated model. A 300 PPD requirement converts to about 141.98 L/day, but still needs its test temperature and RH. The catalogue has no exact 100, 200 or 300 PPD rating; use the actual model values and confirm the duty. Unit conversion does not establish an AHAM/DOE rating.
- Catalogue capacity at 30°C / 80% RH
- 138 L/day
- Rounded US pints/day conversion
- 292 PPD
| Rating basis | Conditions to retain | How to compare |
|---|---|---|
| This catalogue | 30°C / 80% RH | L/day and converted PPD describe the same test condition. |
| AHAM / DOE-labelled data | Ask for the test method, version, temperature and RH. | A unit conversion does not reproduce a different test method or certify a rating. |
| Saturation-labelled data | Ask for the stated temperature and RH; do not infer them from the label. | Request results at matching conditions before comparing with this catalogue. |
ACTUAL OPERATING DUTY
Specify the moisture load before selecting capacity
Record entering-air temperature/RH, target RH, hourly moisture load, required running hours and door opening or infiltration. Include installation position, drainage and power. If the moisture load is unknown, submit the process and room inputs for review instead of assigning units by floor area.
- Entering air and target condition
- Temperature + RH
- Hourly moisture load and running hours
- Water + time
POWER & DRAINAGE
50Hz power, drainage and installation checks
The listed RYCM models specify 220/1ph/50; the RYCF models specify 380/3ph/50. For a site supplied at 220–240V/50Hz or 380–415V/50Hz, provide the actual voltage and phase for model-specific confirmation: the catalogue does not establish acceptance of every voltage in those ranges. Any 60Hz configuration must be confirmed for the project. RYCM-60C lists a 7 L tank and external-hose drainage; the other models list no tank and use an external hose.
- Listed RYCM supply
- 220/1ph/50
- Listed RYCF supply
- 380/3ph/50
- RYCM-60C tank only
- 7 L
Destination and supply
Send the destination country and site electrical schedule. Confirm voltage, phase, frequency and the proposed model together before ordering.
Documents and import scope
List the required product documents, test reports, labels and language. Confirm availability and applicability for the selected configuration, and agree who handles import clearance.
Local installation
Identify who will check local electrical requirements, protection, connection and commissioning. Send deviations from the listed supply for engineering review.
MANUFACTURING & QUOTATION
Manufacturing and project quotation
Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications. For a project quotation, send the candidate model, quantity, destination country, operating condition and site voltage/phase/frequency. Include a nameplate photo or electrical schedule if available. OEM/ODM and configuration requests are reviewed against the equipment requirements.

Purchase and delivery cost
Request an itemised quotation for equipment, selected options, packaging and transport. Confirm MOQ, lead time, delivery destination and shipping terms for that model and order quantity.
Operating cost
Estimate electricity cost from duty-point input power, running hours and the local tariff; include maintenance needs. Catalogue maximum power is not average consumption, and purchase price does not establish running cost.
Agree the quotation scope
Attach the destination-document and installation checklist to your enquiry. Ask which items are included, optional or handled locally so that offers cover the same scope.
INSTALLATION DATA
Model installation and configuration data
| Model | Drainage | Water tank capacity | Machine dimensions | Net weight |
|---|---|---|---|---|
| RYCM-60C | Water tank/External hose | 7 l | 398*386*712 mm | 30 kg |
| RYCM-90C | External hose | None l | 460*360*850 mm | 40 kg |
| RYCM-138C | External hose | None l | 460*360*850 mm | 45 kg |
| RYCF-10S | External hose | None l | 773*401*1613 mm | 100 kg |
| RYCF-12S | External hose | None l | 773*401*1613 mm | 110 kg |
| RYCF-16S | External hose | None l | 1188*437*1778 mm | 180 kg |
| RYCF-22S | External hose | None l | 1188*437*1778 mm | 200 kg |
| RYCF-30S | External hose | None l | 1390*720*1930 mm | 350 kg |
| RYCF-40S | External hose | None l | 1390*720*1930 mm | 400 kg |
PROJECT REVIEW
Send your project selection inputs
Include the following information for a model and configuration review.
Need a custom configuration?- 01
Entering-air temperature/RH and target RH; hourly moisture load or its source
- 02
Operating hours, room volume, door opening, infiltration and air circulation
- 03
Mobile or fixed position, access, drainage route and available voltage / phase / Hz
- 04
Candidate model, quantity, destination country and OEM/ODM or control-interface requirements
FURTHER READING
Selection and application resources
TECHNOLOGY COMPARISON
Refrigerant versus desiccant rotor technology
The Industrial Dehumidifier on this page is part of the Industrial Dehumidifier range; compare the rated values in each model specification table with the working principles below.
| Technology route | How it works | Typical applications |
|---|---|---|
| Refrigerant dehumidification | Cools air below dew point to condense and separate water vapor | Conventional dehumidification duty in commercial and industrial spaces |
| Desiccant rotor dehumidification | Adsorbs moisture onto a rotating wheel and regenerates it continuously | Lower-temperature or lower-humidity targets in storage and process environments |
| Ultrasonic humidification | Adds fine water mist to raise or compensate relative humidity | Humidity compensation in agriculture and process areas |
Application fit
Where this product can be evaluated
Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.
- 01Manufacturing
- 02storage
- 03electrical rooms
- 04warehouses
- 05industrial facilities
Available models
Model range
SELECTION STEPS
How to select the right configuration
- Step 1 — define the operating conditions. Record the temperature range, current and target relative humidity, moisture load, and the volume of the room or enclosure to be protected.
- Step 2 — confirm the site constraints. Check the available power supply, drainage method, airflow or static-pressure requirement, and installation space; for ceiling, cabinet, or portable mounting confirm the fixing method and service access.
- Step 3 — review the rated data and confirm the configuration. Compare the rated capacity in l/24h and the surrounding specification values in the table against the recorded conditions, then confirm the configuration with Yakeclimate before ordering.
FAQ
Frequently Asked Questions
Is the Industrial Dehumidifier capacity rating based on standard testing conditions?
Rated capacity is published under the named condition in the specification table (for example 30°C/80% RH, in l/24h). Actual moisture removal depends on operating temperature, humidity, airflow, and installation conditions.
Which applications can the Industrial Dehumidifier support?
The applications listed on this page are evaluation starting points. Final suitability depends on the moisture load, temperature, airflow, and installation limits of the project.
How does Yakeclimate support project configuration?
We co-develop application-specific dehumidification equipment around the operating conditions, interfaces, and integration requirements of the wider project or system.
How do I size a commercial dehumidifier?
Provide the entering and target air conditions, moisture load, operating hours and infiltration or door-opening conditions. Check model capacity at that duty, then verify the air path, power and drainage.
Do you manufacture industrial dehumidifiers?
Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications. Compare the listed RYCM and RYCF models, or send your equipment requirements for a configuration review.
Which portable industrial dehumidifier should I compare?
Compare RYCM-60C, RYCM-90C and RYCM-138C, rated at 60, 90 and 138 L/day at 30°C/80% RH. Only the 60C lists a 7 L tank; the 90C and 138C list external-hose drainage without a tank.
Is the 138 L/day model a 300 pint dehumidifier?
No. 138 × 2.113 = 291.594, rounded to 292 US pints/day. Compare the rating temperature and humidity as well as the converted capacity.
Can these models use my site's power supply?
Send the country and actual voltage, phase and frequency. The listed RYCM models use 220/1ph/50 and RYCF models use 380/3ph/50. Other voltages or 60Hz configurations require project-specific confirmation.
Project support
Confirm the right configuration for your operating conditions.
Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.
Send project requirements