Compare portable and floor-standing refrigerant dehumidifiers for 50Hz markets and project procurement, with rated capacity, drainage and power data for selection.

Yakeclimate
Industrial Dehumidifier

Product selection should be confirmed against temperature, target humidity, airflow, drainage, power supply, and installation conditions.

DEFINITION

What is an industrial dehumidifier?

Industrial refrigerant dehumidifiers remove moisture from air in manufacturing spaces, warehouses and storage rooms. The RYCM portable and RYCF floor-standing ranges are selected against moisture load, operating temperature/RH, airflow, drainage and the site's power supply.

Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications, with a focus on agriculture and energy projects.

Product overview

How this product family supports a project

Industrial refrigerant dehumidifiers for manufacturing spaces, storage rooms, workshops, and project-based humidity control.

01

Floor-standing and portable configurations for different site layouts.

02

Model selection based on moisture load, temperature, airflow, and drainage conditions.

03

Project quotation and configuration support for industrial environments.

04

Continuous drainage options for long operating cycles.

MODEL SELECTION

Commercial and industrial model range

The RYCM and RYCF ranges cover 60–960 L/day at 30°C/80% RH. Select by actual moisture load and installation conditions, then confirm the model and electrical configuration for your destination.

Rated data by model. Scroll horizontally to review all columns.
ModelL/dayPPD (converted)Rating conditionAirflowPower supply (V / phase / Hz)Maximum power
RYCM-60C 60127 30°C/80% RH 480 m³/h220/1ph/50Max Power: 0.78 kW
RYCM-90C 90190 30°C/80% RH 1000 m³/h220/1ph/50Max Power: 1.35 kW
RYCM-138C 138292 30°C/80% RH 1300 m³/h220/1ph/50Max Power: 1.68 kW
RYCF-10S 240507 30°C/80% RH 2800 m³/h380/3ph/50Max Power: 4.25 kW
RYCF-12S 288609 30°C/80% RH 3000 m³/h380/3ph/50Max Power: 4.65 kW
RYCF-16S 384811 30°C/80% RH 5000 m³/h380/3ph/50Max Power: 6.3 kW
RYCF-22S 4801014 30°C/80% RH 5600 m³/h380/3ph/50Max Power: 8.4 kW
RYCF-30S 7201521 30°C/80% RH 7400 m³/h380/3ph/50Max Power: 12 kW
RYCF-40S 9602028 30°C/80% RH 10000 m³/h380/3ph/50Max Power: 15 kW

PPD means US pints per day, converted as L/day × 2.113 and rounded to the nearest whole number. L/day retains the original rated precision. Conversion is not an AHAM/DOE test result; ratings at different conditions cannot be ranked directly.

INSTALLATION FORMAT

Portable or floor-standing: choose the installation format

Use capacity and the air path together when deciding between mobile and fixed-position equipment. The listed capacities share the 30°C/80% RH rating condition; room area alone cannot determine the number of units.

Yakeclimate industrial dehumidification equipment
Yakeclimate industrial dehumidification equipment
01

Portable RYCM models

Compare RYCM-60C, RYCM-90C and RYCM-138C for mobile or zoned duty: 60, 90 and 138 L/day at 30°C/80% RH. Check moving access and drainage at every intended location. Use the net weights below to plan doorways, thresholds and handling equipment. Before moving, follow the model manual for shutdown and draining retained water.

02

Floor-standing RYCF models

Compare the six RYCF models for a fixed area and larger moisture load, from 240 to 960 L/day at 30°C/80% RH. Check three-phase power, air circulation and an external drain. Confirm the delivery route and handling method against net weight and dimensions. Verify gravity drainage or a pump arrangement for the selected model; an external hose does not establish that a pump is supplied.

03

Overhead or dry-air requirements

If floor space is constrained, review the ceiling-mounted range. For a lower temperature or lower humidity target, compare the desiccant range using the same project conditions.

CAPACITY CONVERSION

Compare L/day and PPD at the same rating condition

138 L/day converts to 291.594 US pints/day, shown as 292 PPD. It is not a 300 PPD rated model. A 300 PPD requirement converts to about 141.98 L/day, but still needs its test temperature and RH. The catalogue has no exact 100, 200 or 300 PPD rating; use the actual model values and confirm the duty. Unit conversion does not establish an AHAM/DOE rating.

Catalogue capacity at 30°C / 80% RH
138 L/day
Rounded US pints/day conversion
292 PPD
Capacity comparison checklist · scroll horizontally on small screens
Rating basisConditions to retainHow to compare
This catalogue30°C / 80% RHL/day and converted PPD describe the same test condition.
AHAM / DOE-labelled dataAsk for the test method, version, temperature and RH.A unit conversion does not reproduce a different test method or certify a rating.
Saturation-labelled dataAsk for the stated temperature and RH; do not infer them from the label.Request results at matching conditions before comparing with this catalogue.

ACTUAL OPERATING DUTY

Specify the moisture load before selecting capacity

Record entering-air temperature/RH, target RH, hourly moisture load, required running hours and door opening or infiltration. Include installation position, drainage and power. If the moisture load is unknown, submit the process and room inputs for review instead of assigning units by floor area.

Entering air and target condition
Temperature + RH
Hourly moisture load and running hours
Water + time

POWER & DRAINAGE

50Hz power, drainage and installation checks

The listed RYCM models specify 220/1ph/50; the RYCF models specify 380/3ph/50. For a site supplied at 220–240V/50Hz or 380–415V/50Hz, provide the actual voltage and phase for model-specific confirmation: the catalogue does not establish acceptance of every voltage in those ranges. Any 60Hz configuration must be confirmed for the project. RYCM-60C lists a 7 L tank and external-hose drainage; the other models list no tank and use an external hose.

Listed RYCM supply
220/1ph/50
Listed RYCF supply
380/3ph/50
RYCM-60C tank only
7 L
01

Destination and supply

Send the destination country and site electrical schedule. Confirm voltage, phase, frequency and the proposed model together before ordering.

02

Documents and import scope

List the required product documents, test reports, labels and language. Confirm availability and applicability for the selected configuration, and agree who handles import clearance.

03

Local installation

Identify who will check local electrical requirements, protection, connection and commissioning. Send deviations from the listed supply for engineering review.

Review equipment requirements

MANUFACTURING & QUOTATION

Manufacturing and project quotation

Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications. For a project quotation, send the candidate model, quantity, destination country, operating condition and site voltage/phase/frequency. Include a nameplate photo or electrical schedule if available. OEM/ODM and configuration requests are reviewed against the equipment requirements.

Yakeclimate production line
Yakeclimate production line
01

Purchase and delivery cost

Request an itemised quotation for equipment, selected options, packaging and transport. Confirm MOQ, lead time, delivery destination and shipping terms for that model and order quantity.

02

Operating cost

Estimate electricity cost from duty-point input power, running hours and the local tariff; include maintenance needs. Catalogue maximum power is not average consumption, and purchase price does not establish running cost.

03

Agree the quotation scope

Attach the destination-document and installation checklist to your enquiry. Ask which items are included, optional or handled locally so that offers cover the same scope.

Destination and installation checklist

INSTALLATION DATA

Model installation and configuration data

ModelDrainageWater tank capacityMachine dimensionsNet weight
RYCM-60CWater tank/External hose7 l398*386*712 mm30 kg
RYCM-90CExternal hoseNone l460*360*850 mm40 kg
RYCM-138CExternal hoseNone l460*360*850 mm45 kg
RYCF-10SExternal hoseNone l773*401*1613 mm100 kg
RYCF-12SExternal hoseNone l773*401*1613 mm110 kg
RYCF-16SExternal hoseNone l1188*437*1778 mm180 kg
RYCF-22SExternal hoseNone l1188*437*1778 mm200 kg
RYCF-30SExternal hoseNone l1390*720*1930 mm350 kg
RYCF-40SExternal hoseNone l1390*720*1930 mm400 kg

PROJECT REVIEW

Send your project selection inputs

Include the following information for a model and configuration review.

Need a custom configuration?
  1. 01

    Entering-air temperature/RH and target RH; hourly moisture load or its source

  2. 02

    Operating hours, room volume, door opening, infiltration and air circulation

  3. 03

    Mobile or fixed position, access, drainage route and available voltage / phase / Hz

  4. 04

    Candidate model, quantity, destination country and OEM/ODM or control-interface requirements

TECHNOLOGY COMPARISON

Refrigerant versus desiccant rotor technology

The Industrial Dehumidifier on this page is part of the Industrial Dehumidifier range; compare the rated values in each model specification table with the working principles below.

Technology route How it works Typical applications
Refrigerant dehumidification Cools air below dew point to condense and separate water vapor Conventional dehumidification duty in commercial and industrial spaces
Desiccant rotor dehumidification Adsorbs moisture onto a rotating wheel and regenerates it continuously Lower-temperature or lower-humidity targets in storage and process environments
Ultrasonic humidification Adds fine water mist to raise or compensate relative humidity Humidity compensation in agriculture and process areas

Application fit

Where this product can be evaluated

Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.

  1. 01Manufacturing
  2. 02storage
  3. 03electrical rooms
  4. 04warehouses
  5. 05industrial facilities

SELECTION STEPS

How to select the right configuration

  1. Step 1 — define the operating conditions. Record the temperature range, current and target relative humidity, moisture load, and the volume of the room or enclosure to be protected.
  2. Step 2 — confirm the site constraints. Check the available power supply, drainage method, airflow or static-pressure requirement, and installation space; for ceiling, cabinet, or portable mounting confirm the fixing method and service access.
  3. Step 3 — review the rated data and confirm the configuration. Compare the rated capacity in l/24h and the surrounding specification values in the table against the recorded conditions, then confirm the configuration with Yakeclimate before ordering.

FAQ

Frequently Asked Questions

Is the Industrial Dehumidifier capacity rating based on standard testing conditions?

Rated capacity is published under the named condition in the specification table (for example 30°C/80% RH, in l/24h). Actual moisture removal depends on operating temperature, humidity, airflow, and installation conditions.

Which applications can the Industrial Dehumidifier support?

The applications listed on this page are evaluation starting points. Final suitability depends on the moisture load, temperature, airflow, and installation limits of the project.

How does Yakeclimate support project configuration?

We co-develop application-specific dehumidification equipment around the operating conditions, interfaces, and integration requirements of the wider project or system.

How do I size a commercial dehumidifier?

Provide the entering and target air conditions, moisture load, operating hours and infiltration or door-opening conditions. Check model capacity at that duty, then verify the air path, power and drainage.

Do you manufacture industrial dehumidifiers?

Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications. Compare the listed RYCM and RYCF models, or send your equipment requirements for a configuration review.

Which portable industrial dehumidifier should I compare?

Compare RYCM-60C, RYCM-90C and RYCM-138C, rated at 60, 90 and 138 L/day at 30°C/80% RH. Only the 60C lists a 7 L tank; the 90C and 138C list external-hose drainage without a tank.

Is the 138 L/day model a 300 pint dehumidifier?

No. 138 × 2.113 = 291.594, rounded to 292 US pints/day. Compare the rating temperature and humidity as well as the converted capacity.

Can these models use my site's power supply?

Send the country and actual voltage, phase and frequency. The listed RYCM models use 220/1ph/50 and RYCF models use 380/3ph/50. Other voltages or 60Hz configurations require project-specific confirmation.

Project support

Confirm the right configuration for your operating conditions.

Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.