Ceiling Dehumidifier

RYDZ-12S

Ceiling Dehumidifier – 288L per 24hr refrigerant dehumidifier

RYDZ-12S is a ceiling dehumidifier with a rated output of 288 l/24h and an airflow reference of 3000 m³/h, intended for commercial and industrial spaces where ceiling installation preserves floor area. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, drainage, power supply, and installation conditions.

Dehumidification Capacity
288 l/24h
Air Volume
3000 m³/h
Power Supply
380/3ph/50 V/Hz
Applicable Temperature
5-38 °C
RYDZ-12S
RYDZ-12S – Ceiling Dehumidifier – 288L per 24hr refrigerant dehumidifier

Product selection should be confirmed against temperature, target humidity, airflow, drainage, power supply, and installation conditions.

DEFINITION

What is an industrial dehumidifier?

An industrial dehumidifier is a humidity-control device that removes water vapor from ambient or process air and holds relative humidity at a defined operating level. Industrial models are specified against the operating temperature, target humidity, airflow, drainage, and power supply of a project rather than by floor area alone.

RYDZ-12S is a Ceiling Dehumidifier unit with a published rated capacity of 288 l/24h on this page.

Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications, with a focus on agriculture and energy projects.

Product overview

What RYDZ-12S is designed to do

RYDZ-12S is a ceiling dehumidifier with a rated output of 288 l/24h and an airflow reference of 3000 m³/h, intended for commercial and industrial spaces where ceiling installation preserves floor area. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, drainage, power supply, and installation conditions.

01

Automatic dehumidification mode

02

High efficiency dehumidification capacity with branded compressor

03

Intelligent controller panel & remote control

04

Strong copper motor with high air volume

05

Automatic drainage function

06

High durability metal shell

07

Timer on/off function

08

Ceiling installation saves floor space

Technical data

Product specifications

Values below are retained from the current product record. Final configuration should be confirmed in the project quotation.

Specification Unit RYDZ-12S
Power Supply V/Hz 380/3ph/50
Dehumidification Capacity(30°C/80% RH) l/24h 288
Maximum Power kW 4.65
Input Current A 7.5
Air Volume m³/h 3000
External Pressure Pa 120
Filtration Device Primary Efficiency
Applicable Temperature °C 5-38
Drainage Method External Hose Drainage
Control Method 86*86 Box Controller
Refrigerant R22/R410A
Noise Level dB(A) ≤65
Return Air Outlet Diameter mm 604*554
Supply Air Outlet Diameter mm 604*554
Machine Dimensions mm 1100*900*700
Net Weight kg 126

TECHNOLOGY COMPARISON

Refrigerant versus desiccant rotor technology

The RYDZ-12S on this page is a Ceiling Dehumidifier unit; compare its published ratings in the specification table with the working principles below.

Technology route How it works Typical applications
Refrigerant dehumidification Cools air below dew point to condense and separate water vapor Conventional dehumidification duty in commercial and industrial spaces
Desiccant rotor dehumidification Adsorbs moisture onto a rotating wheel and regenerates it continuously Lower-temperature or lower-humidity targets in storage and process environments
Ultrasonic humidification Adds fine water mist to raise or compensate relative humidity Humidity compensation in agriculture and process areas

Application fit

Where this product can be evaluated

Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.

  1. 01Agriculture
  2. 02Buildings and commercial spaces
  3. 03Data centres and telecoms
  4. 04Food and beverage
  5. 05General industry and production
  6. 06Leisure and recreation
  7. 07Museum and gallery preservation
  8. 08Pharmaceutical and scientific
  9. 09Storage, preservation and archives

SELECTION STEPS

How to select the right configuration

  1. Step 1 — define the operating conditions. Record the temperature range, current and target relative humidity, moisture load, and the volume of the room or enclosure to be protected.
  2. Step 2 — confirm the site constraints. Check the available power supply, drainage method, airflow or static-pressure requirement, and installation space; for ceiling, cabinet, or portable mounting confirm the fixing method and service access.
  3. Step 3 — review the rated data and confirm the configuration. Compare the rated capacity in l/24h and the surrounding specification values in the table against the recorded conditions, then confirm the configuration with Yakeclimate before ordering.

FAQ

Frequently Asked Questions

Is the RYDZ-12S capacity rating based on standard testing conditions?

Rated capacity is published under the named condition in the specification table (for example 30°C/80% RH, in l/24h). Actual moisture removal depends on operating temperature, humidity, airflow, and installation conditions.

Which applications can the RYDZ-12S support?

The applications listed on this page are evaluation starting points. Final suitability depends on the moisture load, temperature, airflow, and installation limits of the project.

How does Yakeclimate support project configuration?

We co-develop application-specific dehumidification equipment around the operating conditions, interfaces, and integration requirements of the wider project or system.

Project support

Confirm the right configuration for your operating conditions.

Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.

Send project requirements