Ultrasonic Humidifier

RYJS-78D

Ultrasonic Humidifier – 78kg/h Output Humidifier

RYJS-78D is an ultrasonic humidifier with a rated output of 78 kg/h, intended for controlled environments that require industrial humidity compensation. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, drainage, power supply, and installation conditions.

Humidification Capacity
78 kg/h
Power Supply
380/50 V/Hz
Rated Power
7.8 kW
Adjustable Humidity Range
10-95 RH %
RYJS-78D
RYJS-78D – Ultrasonic Humidifier – 78kg/h Output Humidifier

Product selection should be confirmed against temperature, target humidity, airflow, drainage, power supply, and installation conditions.

DEFINITION

What is an industrial dehumidifier?

An industrial dehumidifier is a humidity-control device that removes water vapor from ambient or process air and holds relative humidity at a defined operating level. Industrial models are specified against the operating temperature, target humidity, airflow, drainage, and power supply of a project rather than by floor area alone.

RYJS-78D is a Ultrasonic Humidifier unit with a published rated capacity of 78 kg/h on this page.

Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications, with a focus on agriculture and energy projects.

Product overview

What RYJS-78D is designed to do

RYJS-78D is an ultrasonic humidifier with a rated output of 78 kg/h, intended for controlled environments that require industrial humidity compensation. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, drainage, power supply, and installation conditions.

01

Automatic humidity control with a digital display and an adjustable setpoint range of 10–95% RH

02

Fine mist output with a particle size of up to 10 μm

03

Automatic water inlet and water-level control

04

Automatic stop at the humidity setpoint and restart when humidity falls below the setpoint

05

Power-off memory and timer control

06

External humidity sensor can be installed separately from the unit

Technical data

Product specifications

Values below are retained from the current product record. Final configuration should be confirmed in the project quotation.

Specification Unit RYJS-78D
Power Supply V/Hz 380/50
Humidification Capacity kg/h 78
Fog Particle Size μm ≤10
Rated Power kW 7.8
Adjustable Humidity Range RH % 10-95
Fog Outlet Diameter mm 160*3
Timer Function Timer control
Control Method Humidity automatic control
Dimensions mm 950*900*600
Machine Weight kg 80

TECHNOLOGY COMPARISON

Refrigerant versus desiccant rotor technology

The RYJS-78D on this page is a Ultrasonic Humidifier unit; compare its published ratings in the specification table with the working principles below.

Technology route How it works Typical applications
Refrigerant dehumidification Cools air below dew point to condense and separate water vapor Conventional dehumidification duty in commercial and industrial spaces
Desiccant rotor dehumidification Adsorbs moisture onto a rotating wheel and regenerates it continuously Lower-temperature or lower-humidity targets in storage and process environments
Ultrasonic humidification Adds fine water mist to raise or compensate relative humidity Humidity compensation in agriculture and process areas

Application fit

Where this product can be evaluated

Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.

  1. 01Healthcare
  2. 02Manufacturing
  3. 03Agriculture
  4. 04Food
  5. 05Printing
  6. 06Museums and Art Galleries
  7. 07Woodworking
  8. 08Textile
  9. 09Warehouses and storage
  10. 10Hospitality

SELECTION STEPS

How to select the right configuration

  1. Step 1 — define the operating conditions. Record the temperature range, current and target relative humidity, moisture load, and the volume of the room or enclosure to be protected.
  2. Step 2 — confirm the site constraints. Check the available power supply, drainage method, airflow or static-pressure requirement, and installation space; for ceiling, cabinet, or portable mounting confirm the fixing method and service access.
  3. Step 3 — review the rated data and confirm the configuration. Compare the rated capacity in l/24h and the surrounding specification values in the table against the recorded conditions, then confirm the configuration with Yakeclimate before ordering.

FAQ

Frequently Asked Questions

Is the RYJS-78D capacity rating based on standard testing conditions?

Rated capacity is published under the named condition in the specification table (for example 30°C/80% RH, in l/24h). Actual moisture removal depends on operating temperature, humidity, airflow, and installation conditions.

Which applications can the RYJS-78D support?

The applications listed on this page are evaluation starting points. Final suitability depends on the moisture load, temperature, airflow, and installation limits of the project.

How does Yakeclimate support project configuration?

We co-develop application-specific dehumidification equipment around the operating conditions, interfaces, and integration requirements of the wider project or system.

Project support

Confirm the right configuration for your operating conditions.

Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.

Send project requirements