Ultrasonic Humidifier

RYJS-102D

Ultrasonic Humidifier – 102kg/h Output Humidifier

RYJS-102D is an ultrasonic humidifier with a rated output of 102 kg/h, intended for controlled environments that require industrial humidity compensation. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, drainage, power supply, and installation conditions.

Humidification Capacity
102 kg/h
Power Supply
380/50 V/Hz
Rated Power
10.2 kW
Adjustable Humidity Range
10-95 RH %
RYJS-102D
RYJS-102D – Ultrasonic Humidifier – 102kg/h Output Humidifier

Product selection should be confirmed against temperature, target humidity, airflow, drainage, power supply, and installation conditions.

Product overview

What RYJS-102D is designed to do

RYJS-102D is an ultrasonic humidifier with a rated output of 102 kg/h, intended for controlled environments that require industrial humidity compensation. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, drainage, power supply, and installation conditions.

01

Automatic humidity control with a digital display and an adjustable setpoint range of 10–95% RH

02

Fine mist output with a particle size of up to 10 μm

03

Automatic water inlet and water-level control

04

Automatic stop at the humidity setpoint and restart when humidity falls below the setpoint

05

Power-off memory and timer control

06

External humidity sensor can be installed separately from the unit

Technical data

Product specifications

Values below are retained from the current product record. Final configuration should be confirmed in the project quotation.

Specification Unit RYJS-102D
Power Supply V/Hz 380/50
Humidification Capacity kg/h 102
Fog Particle Size μm ≤10
Rated Power kW 10.2
Adjustable Humidity Range RH % 10-95
Fog Outlet Diameter mm 160*3
Timer Function Timer control
Control Method Humidity automatic control
Dimensions mm 950*900*600
Machine Weight kg 100

Application fit

Where this product can be evaluated

Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.

  1. 01Healthcare
  2. 02Manufacturing
  3. 03Agriculture
  4. 04Food
  5. 05Printing
  6. 06Museums and Art Galleries
  7. 07Woodworking
  8. 08Textile
  9. 09Warehouses and storage
  10. 10Hospitality

Project support

Confirm the right configuration for your operating conditions.

Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.

Send project requirements