Ultrasonic Humidifier

RYJS-12D

Ultrasonic Humidifier – 12kg/h Output Humidifier

RYJS-12D is an ultrasonic humidifier with a rated output of 12 kg/h, intended for controlled environments that require industrial humidity compensation. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, water quality and supply, airflow, mist absorption distance, power supply, and control requirements.

Humidification Capacity
12 kg/h
Power Supply
220/1ph/50 V/Hz
Rated Power
0.655 kW
Adjustable Humidity Range
10-95 RH %
RYJS-12D
RYJS-12D – Ultrasonic Humidifier – 12kg/h Output Humidifier

Confirm humidification output, water quality and supply, mist absorption distance, airflow, power supply and controls for the project.

DEFINITION

What is an ultrasonic humidifier?

An ultrasonic humidifier adds moisture to air as fine water mist without a heating process. This family provides humidity compensation for greenhouses, textile applications, cold storage and other controlled environments. Selection depends on the required humidification output, water quality, airflow, room conditions and installation position; automatic humidity-control functions vary by model and configuration.

Confirm humidification output, water quality and supply, mist absorption distance, airflow, power supply and controls for the project.

RYJS-12D has a published humidification output of 12 kg/h. Confirm rating conditions and the required output for the project before selection.

Product overview

What RYJS-12D is designed to do

RYJS-12D is an ultrasonic humidifier with a rated output of 12 kg/h, intended for controlled environments that require industrial humidity compensation. Use the technical data below as a starting point, then confirm the configuration against the actual temperature, humidity target, water quality and supply, airflow, mist absorption distance, power supply, and control requirements.

01

Low Energy Consumption and Sufficient Power: Built-in super-energy atomizing and humidifying parts, high energy efficiency ratio, large atomizing amount, and atomizing particles are only 1-5um

02

Automatic & Multi-mount Way: The operating system of the machine is a fully automatic digital display control system with control accuracy within ±5%. The bottom of the machine is equipped with casters for easy movement. It can also be mounted on the wall. It is made of high quality stainless steel

03

Safety and Intelligence: Leakage protection.Over-temperature power-off protection.Automatic water level detection of humidification module. Automatic protection against water shortage.Portable ultrasonic humidifier with digital controlling panel, you can adjust humidifying capacity and operation time as your desire

04

Strong anti-interference: Industrial grade waterproof, dustproof and anti-interference.Waterproof fog-blowing fan can blow out mist evenly.The temperature detection sensor probe resistant to high temperature and high humidity

Technical data

Product specifications

Values below are retained from the current product record. Final configuration should be confirmed in the project quotation.

Specification Unit RYJS-12D
Power Supply V/Hz 220/1ph/50
Humidification Capacity kg/h 12
Rated Power kW 0.655
Adjustable Humidity Range RH % 10-95
Fog Outlet Diameter mm 110*2
Timer Function — 24-hour timed on/off
Control Method — Humidity automatic control
Dimensions mm 509*385*306
Machine Weight kg 22.5

HUMIDIFICATION SELECTION

Match humidification output, water supply and mist distribution

Use the published model data to compare output and controls, then confirm water supply and mist distribution against the installation conditions.

Selection input Published data or project input Confirm for the project
Humidification output 12 kg/h Required moisture addition and rating conditions
Water quality and supply Provide the available water source and water-quality information Water treatment, supply pressure and maintenance requirements
Mist distribution and controls Review the model's fog outlet and control-method specifications Absorption distance, airflow path, sensor location and control interfaces

Application fit

Where this product can be evaluated

Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.

  1. 01Healthcare
  2. 02Manufacturing
  3. 03Agriculture
  4. 04Food
  5. 05Printing
  6. 06Museums and Art Galleries
  7. 07Woodworking
  8. 08Textile
  9. 09Warehouses and storage
  10. 10Hospitality

SELECTION STEPS

How to select the right configuration

  1. Step 1 — define the humidification requirement. Provide the operating temperature, current and target relative humidity, room volume and ventilation conditions so the required moisture addition can be reviewed.
  2. Step 2 — review water supply and mist distribution. Provide water-quality information, available supply conditions, the airflow path and outlet position. Confirm water treatment, supply pressure and mist absorption distance for the project.
  3. Step 3 — compare humidification output in kg/h. Review the model's published output, power supply and control method. Confirm rating conditions, humidity-sensor location and any external control interface before ordering.

FAQ

Frequently Asked Questions

How much humidification output does the project need?

The published humidification output for RYJS-12D is 12 kg/h. Provide temperature, current and target humidity, room volume and ventilation conditions for an output review. Confirm rating conditions and final selection for the project; floor area alone is not enough.

What water quality and supply are required?

Provide the water source, available water-quality analysis and supply conditions. Water treatment, inlet pressure and maintenance requirements must be confirmed for the model and project before ordering.

What mist absorption distance and control arrangement should be planned?

Provide the outlet layout, airflow path, temperature, target humidity and nearby surfaces for review. Confirm the mist absorption distance for these conditions. The model tables list automatic humidity control; confirm sensor placement and any required external control interface for the selected configuration.

Project support

Confirm the right configuration for your operating conditions.

Share the operating temperature, current and target humidity, room dimensions, ventilation, water quality and supply, outlet layout, power supply and control requirements. Yakeclimate can review the humidification output and configuration for your project.

Send project requirements