Energy Storage Dehumidifier

ADS-10DW2

Energy storage refrigerant dehumidifier – 10 L/24h

ADS-10DW2 is a compact dehumidifier for battery cabinets, electrical enclosures and energy-storage equipment. Its published removal rating is 10 L/24h at 30 °C and 80% RH; final selection should be confirmed against the actual temperature, humidity or dew-point target, moisture load, drainage, power, control and installation conditions.

Dehumidification Capacity
10 L/24h
Rated Power
185 W
Operating Temperature
5–40 °C
Power Supply
AC 220V 50Hz
ADS-10DW2
ADS-10DW2 – Energy storage refrigerant dehumidifier – 10 L/24h

Product selection should be confirmed against temperature, target humidity, airflow, drainage, power supply, and installation conditions.

DEFINITION

What is an industrial dehumidifier?

An industrial dehumidifier is a humidity-control device that removes water vapor from ambient or process air and holds relative humidity at a defined operating level. Industrial models are specified against the operating temperature, target humidity, airflow, drainage, and power supply of a project rather than by floor area alone.

ADS-10DW2 is a Energy Storage Dehumidifier unit with a published rated capacity of 10 L/24h on this page.

Yakeclimate designs and manufactures industrial dehumidification equipment for complex climate applications, with a focus on agriculture and energy projects.

Product overview

What ADS-10DW2 is designed to do

ADS-10DW2 is a compact dehumidifier for battery cabinets, electrical enclosures and energy-storage equipment. Its published removal rating is 10 L/24h at 30 °C and 80% RH; final selection should be confirmed against the actual temperature, humidity or dew-point target, moisture load, drainage, power, control and installation conditions.

01

10 L/24h rated moisture removal at 30 °C and 80% RH

02

R134A refrigerant system with primary filtration

03

RS485 communication

04

Direct external drainage

05

Published operating range from 5 °C to 40 °C

Technical data

Product specifications

Values below are retained from the current product record. Final configuration should be confirmed in the project quotation.

Specification Unit ADS-10DW2
Dehumidification Capacity (30°C/80% RH) L/24h 10
Power Supply V/Hz AC 220V 50Hz
Rated Power W 185
Rated Current A 0.84
Airflow m³/h 100
Refrigerant R134A
Filter Primary filtration
Communication RS485
Drainage Method Direct external drainage
Operating Temperature °C 5–40
Machine Dimensions (L×W×H) mm 277 × 181 × 406
Net Weight kg 14

TECHNOLOGY COMPARISON

Refrigerant versus desiccant rotor technology

The ADS-10DW2 on this page is a Energy Storage Dehumidifier unit; compare its published ratings in the specification table with the working principles below.

Technology route How it works Typical applications
Refrigerant dehumidification Cools air below dew point to condense and separate water vapor Conventional dehumidification duty in commercial and industrial spaces
Desiccant rotor dehumidification Adsorbs moisture onto a rotating wheel and regenerates it continuously Lower-temperature or lower-humidity targets in storage and process environments
Ultrasonic humidification Adds fine water mist to raise or compensate relative humidity Humidity compensation in agriculture and process areas

Application fit

Where this product can be evaluated

Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.

  1. 01Battery cabinets
  2. 02Electrical enclosures
  3. 03Energy-storage equipment

SELECTION STEPS

How to select the right configuration

  1. Step 1 — define the operating conditions. Record the temperature range, current and target relative humidity, moisture load, and the volume of the room or enclosure to be protected.
  2. Step 2 — confirm the site constraints. Check the available power supply, drainage method, airflow or static-pressure requirement, and installation space; for ceiling, cabinet, or portable mounting confirm the fixing method and service access.
  3. Step 3 — review the rated data and confirm the configuration. Compare the rated capacity in l/24h and the surrounding specification values in the table against the recorded conditions, then confirm the configuration with Yakeclimate before ordering.

FAQ

Frequently Asked Questions

Is the ADS-10DW2 capacity rating based on standard testing conditions?

Rated capacity is published under the named condition in the specification table (for example 30°C/80% RH, in l/24h). Actual moisture removal depends on operating temperature, humidity, airflow, and installation conditions.

Which applications can the ADS-10DW2 support?

The applications listed on this page are evaluation starting points. Final suitability depends on the moisture load, temperature, airflow, and installation limits of the project.

How does Yakeclimate support project configuration?

We co-develop application-specific dehumidification equipment around the operating conditions, interfaces, and integration requirements of the wider project or system.

Project support

Confirm the right configuration for your operating conditions.

Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.

Send project requirements