Energy Storage Dehumidifier
ADS-10DW2
Energy storage refrigerant dehumidifier – 10 L/day
ADS-10DW2 removes 10 L of water a day at 30°C/80% RH, with 100 m³/h airflow and an AC 220 V 50 Hz supply.
- Dehumidification Capacity
- 10 L/day
- Rated Power
- 185 W
- Operating Temperature
- 5–40 °C
- Power Supply
- AC 220V 50Hz

An industrial dehumidifier is a humidity-control device that removes water vapor from ambient or process air and holds relative humidity at a defined operating level.
Product overview
What ADS-10DW2 is designed to do
ADS-10DW2 removes 10 L of water a day at 30°C/80% RH, with 100 m³/h airflow and an AC 220 V 50 Hz supply.
10 L/day rated moisture removal at 30 °C and 80% RH
R134A refrigerant system with primary filtration
RS485 communication
Direct external drainage
Published operating range from 5 °C to 40 °C
Technical data
Product specifications
| Specification | Unit | ADS-10DW2 |
|---|---|---|
| Dehumidification Capacity (30°C/80% RH) | L/day | 10 |
| Power Supply | — | AC 220V 50Hz |
| Rated Power | W | 185 |
| Rated Current | A | 0.84 |
| Airflow | m³/h | 100 |
| Refrigerant | — | R134A |
| Filter | — | Primary filtration |
| Communication | — | RS485 |
| Drainage Method | — | Direct external drainage |
| Operating Temperature | °C | 5–40 |
| Machine Dimensions (L×W×H) | mm | 277 × 181 × 406 |
| Net Weight | kg | 14 |
TECHNOLOGY COMPARISON
Refrigerant versus desiccant rotor technology
The ADS-10DW2 on this page is an Energy Storage Dehumidifier unit; compare its published ratings in the specification table with the working principles below.
| Technology route | How it works | Typical applications |
|---|---|---|
| Refrigerant dehumidification | Cools air below dew point to condense and separate water vapor | Conventional dehumidification duty in commercial and industrial spaces |
| Desiccant rotor dehumidification | Adsorbs moisture onto a rotating wheel and regenerates it continuously | Lower-temperature or lower-humidity targets in storage and process environments |
| Ultrasonic humidification | Adds fine water mist to raise or compensate relative humidity | Humidity compensation in agriculture and process areas |
Application fit
Where this product can be evaluated
Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.
- 01Battery cabinets
- 02Electrical enclosures
- 03Energy-storage equipment
Compare the range
Other Energy Storage Dehumidifier models



SELECTION STEPS
How to select the right configuration
- Step 1 — define the operating conditions. Record the temperature range, current and target relative humidity, moisture load, and the volume of the room or enclosure to be protected.
- Step 2 — confirm the site constraints. Check the available power supply, drainage method, airflow or static-pressure requirement, and installation space; for ceiling, cabinet, or portable mounting confirm the fixing method and service access.
- Step 3 — review the rated data and confirm the configuration. Compare the rated capacity in L/day and the surrounding specification values in the table against the recorded conditions, then confirm the configuration with Yakeclimate before ordering.
Product definition and technical notes
What is an industrial dehumidifier?
An industrial dehumidifier is a humidity-control device that removes water vapor from ambient or process air and holds relative humidity at a defined operating level. Industrial models are specified against the operating temperature, target humidity, airflow, drainage, and power supply of a project rather than by floor area alone.
ADS-10DW2 is an Energy Storage Dehumidifier unit with a published rated capacity of 10 L/day on this page.
Company record behind this product
Since 2010, Yakeclimate has supplied customers in 50+ countries and regions, and holds 46+ patents supporting product and application development alongside a national-level laboratory. The specification values on this page are published from the current product record and reviewed against project conditions before quotation.
FAQ
Frequently Asked Questions
Is the ADS-10DW2 capacity rating based on standard testing conditions?
Rated capacity is published under the named condition in the specification table (for example 30°C/80% RH, in L/day). Actual moisture removal depends on operating temperature, humidity, airflow, and installation conditions.
Which applications can the ADS-10DW2 support?
The applications listed on this page are evaluation starting points. Final suitability depends on the moisture load, temperature, airflow, and installation limits of the project.
How does Yakeclimate support project configuration?
Project support
Confirm the right configuration for your operating conditions.
Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.
Send project requirements