Agriculture & Controlled Environments

Vertical Farming Equipment Guide: What a Farm Needs and How It Fits Together

Vertical farming equipment explained: racks, LED lighting, hydroponic or aeroponic irrigation, HVAC and dehumidification, CO₂, sensors and controls, with a worked heat and water balance.

Written byYakeclimate Engineering TeamEngineering TeamReviewed by Jordan Shao, R&D Director
Illustration of air branches and canopy sensors on three growing tiers.

Quick answer: A vertical farm needs seven equipment systems: growing racks, LED lighting, an irrigation system (NFT, deep-water culture, ebb-and-flow or aeroponics), climate control (cooling, heating and dehumidification), CO₂ enrichment, water treatment, and sensors with a control system. The climate system is usually the hardest part to get right: almost all lighting power becomes heat, and almost all irrigation water the plants take up comes back out as humidity, so cooling and dehumidification must be sized together.

Quick answer
  • Seven systems: racks, LEDs, irrigation, climate (HVAC + dehumidification), CO₂, water treatment, controls.
  • The LED load sets the cooling; crop transpiration sets the dehumidification.
  • Recovered condensate can return to irrigation, which is how vertical farms use so little water.

The seven equipment systems

SystemOptionsWhat to decide
Racks and growing structureStatic multi-tier racks, mobile racks, towersTier spacing, aisle access, load rating, materials that tolerate humidity
LightingLED fixtures with crop-specific spectraLight intensity (PPFD) and daily light integral per crop; efficacy in µmol/J; heat removal
IrrigationNFT channels, deep-water culture, ebb-and-flow trays, aeroponics, dripCrop, root health, pumps, redundancy
Nutrient and water treatmentDosing, pH/EC control, filtration, UV or other disinfectionWater quality, recirculation, condensate reuse
Climate controlCooling, heating, dehumidification, air circulation per tierTemperature, humidity/VPD, air speed at the canopy
CO₂Bulk tank or generator, dosing, sensorsEnrichment level and air-tightness of the room
Sensors and controlsTemperature, RH, CO₂, PAR, water level, pH/EC; climate computerSensor per zone and tier; alarms; data logging

Why climate control is the critical system

In a closed growing room, there is no sun and little ventilation. Two balances decide the equipment:

Heat: almost all the electricity used by LEDs, pumps and fans ends up as heat in the room. Some of it is used to evaporate water from leaves (latent heat); the rest warms the air (sensible heat).

Water: the water plants take up through their roots is released through their leaves. In a recirculating system:

crop transpiration ≈ irrigation supplied − drainage − change in stored water

That transpired water must be removed from the air, by cooling coils, dehumidifiers or both. Wageningen research on plant factories analysed this crop transpiration and energy balance in detail (WUR, Plant factories: crop transpiration and energy balance).

Worked example (illustrative)

A farm with 500 m² of canopy (five tiers of 100 m²), growing leafy greens. Assumptions for this example: crop transpiration 3 L per m² per day; LEDs at about 90 W per m² for 16 hours.

  • Water to remove: 500 × 3 = 1,500 L/day, mostly during lights-on, about 80 L/h at the peak.
  • Latent heat in that water: about 0.68 kWh per litre, roughly 55 kW at the peak, which the climate system removes when it condenses the water.
  • LED power: 500 × 90 W ≈ 45 kW while lights are on, almost all of it becoming heat.

So the cooling and dehumidification equipment must handle tens of kilowatts and hundreds of litres a day. And the hard period is often lights-off: cooling demand falls, cooling coils stop removing water, and humidity rises unless dedicated dehumidifiers run.

Vertical farming HVAC: common layouts

LayoutHow it worksSuitsWatch
Split or packaged AC + separate dehumidifiersAC handles heat; dehumidifiers hold humidity, including lights-offSmall and medium rooms, container farmsCoordinate controls so they don't fight
Chilled-water fan coils + dehumidifiersCentral chiller; fan coils per room or tierLarger farmsCoil temperature sets how much moisture fan coils remove
Integrated climate units (cooling + dehumidification + reheat)One unit controls temperature and humidityFarms wanting one control pointSize for both lights-on and lights-off
Dedicated outdoor air system (DOAS)Treats fresh air separatelyFarms needing ventilationFresh air adds moisture and heat in summer

Whatever the layout, check lights-off: cooling demand drops sharply while plants still transpire, so humidity control must work without the cooling load.

Dehumidification options

OptionFits whenNotes
HVAC cooling coils onlyLights-on, high cooling loadRemoves water while cooling; weak at lights-off
Dedicated dehumidifiers in the roomLights-off and transition periods; extra capacityAdds heat; must be included in cooling design
Ducted dehumidifiers outside the roomKeeping service out of the growing areaDuct pressure, air distribution to each tier
Integrated HVAC with dehumidification and reheatLarge farmsHigher first cost; best control

Size dehumidifiers at the room condition (for example 22–24 °C and 60–70 % RH), not at the 30 °C / 80 % RH rating. Our ceiling-mounted and ducted dehumidifiers (26–960 L/day) suit multi-tier rooms where floor space is used for racks. See grow room dehumidifier sizing and placement.

Air distribution between tiers

Upper tiers are often warmer and drier, lower tiers cooler and more humid. Without air delivered to each tier, the canopy in the middle of a rack can stay humid even when the room sensor looks fine. Use:

  • fans or perforated ducts along each tier;
  • air speed at the canopy of roughly 0.3–1.0 m/s for leafy greens (helps transpiration and reduces tipburn);
  • sensors at several tier heights.

Water recovery

Condensate from cooling coils and dehumidifiers is close to the volume the crop transpires: in the example, about 1,500 L/day. Returned to the irrigation system after filtering and disinfection, it cuts fresh water use sharply. Plan the condensate collection, storage and treatment at the design stage.

Fertigation and irrigation

Fertigation combines irrigation and nutrient dosing: a mixing tank, dosing pumps for nutrient concentrates and pH adjustment, EC and pH sensors, filtration, disinfection (UV or similar), and pumps to each tier. Decide recirculation (with treatment) or drain-to-waste, and redundancy for pumps. Irrigation volume minus drainage is a good estimate of the dehumidification load.

Gas detection and safety

  • CO₂ enrichment to around 800–1,200 ppm is common for leafy greens. Higher levels are a worker hazard: OSHA's permissible exposure limit for CO₂ is 5,000 ppm (8-hour average). Use CO₂ sensors with alarms at the working level, and interlock dosing with ventilation.
  • Refrigerant leak detection where large charges or flammable refrigerants are used, per local codes.
  • Water leak detection under racks and around tanks.

Power distribution

LED lighting is usually the largest electrical load, followed by HVAC. Plan dedicated circuits per tier or zone, distribution boards near the racks, LED driver location (heat), and backup power for controls, pumps and climate so a power cut doesn't cook or dry the crop.

Control system integration

One climate and fertigation controller, or integrated controllers, with sensors per zone and tier, alarms by phone, and data logging. Agree which device has authority over temperature, humidity and CO₂ so systems don't fight.

Maintenance and sanitation

Clean trays and channels between crops; disinfect irrigation lines; replace filters on HVAC and dehumidifiers; check sensors against a reference; clean condensate drains (biofilm); keep spare pumps and sensors.

Equipment checklist for a vertical farm

  • Crop list, tier count, canopy area and growing cycle
  • Light intensity and photoperiod per crop
  • Irrigation type and water treatment
  • Room temperature, humidity/VPD and CO₂ targets for lights-on and lights-off
  • Cooling and dehumidification capacity at both periods
  • Air distribution per tier
  • Condensate recovery route
  • Sensors, control system and alarms
  • Redundancy for pumps, cooling and dehumidification

Related: lettuce and leafy greens humidity and hydroponic greenhouse humidity.

FAQ

Frequently asked questions

What equipment do you need for vertical farming?

Racks, LED lighting, a hydroponic or aeroponic irrigation system, nutrient and water treatment, climate control (cooling, heating and dehumidification), CO₂ enrichment, and sensors with a control system.

What HVAC does a vertical farm need?

Cooling sized for the LED heat, plus dehumidification sized for crop transpiration that works when lights are off; see the layouts above.

What is climate-controlled farming?

Growing crops indoors (vertical farms, container farms, grow rooms) where temperature, humidity, CO₂, light and airflow are controlled by equipment rather than the weather.

What supplies and tools does an indoor farm need besides the main systems?

Trays, growing media, seeds, nutrients, pH and EC meters, cleaning and sanitising supplies, spare filters, calibration tools for sensors, and harvest and packing equipment.

What are vertical farming units?

Self-contained growing modules or containers with racks, lights, irrigation and climate control built in; they need the same climate sizing as a room.

Why do vertical farms need dehumidifiers?

Plants release almost all the water they absorb into the air. In a closed room, that water must be removed, especially when lights are off and cooling stops.

How much water does a vertical farm use?

Far less than field growing when condensate is recovered, because the water the crop transpires is condensed and returned to irrigation.

What is the biggest energy use in a vertical farm?

Usually lighting, followed by the cooling and dehumidification that remove the heat and moisture the lights and crop produce.

Sources

  • Wageningen University & Research, Plant factories: crop transpiration and energy balance.
  • Frontiers in Sustainable Food Systems (2023), vertical farming review.
  • US EPA, vertical farming research report.
  • University of Kentucky Center for Crop Diversification, Hydroponic lettuce (air speed).
  • OSHA, Carbon dioxide permissible exposure limit (29 CFR 1910.1000, Table Z-1).

About the author

Yakeclimate Engineering Team

Engineering Team

Yakeclimate technical articles are prepared by the engineering team using inputs from product development, application review, manufacturing, testing, and project support.

View author profile

Reviewed by Jordan Shao, R&D Director

Continue reading

More on agriculture & controlled environments

Project evidence

Related case studies

Project support

Ready to turn the operating conditions into a project brief?

Use the project-input checklist to help our team review the environment, moisture load, interfaces, installation limits, and validation needs from one consistent brief.
Send project requirements