Wind Power Dehumidifier

ADS-500M

Wind power desiccant dehumidifier – 2.5 kg/h rated moisture removal

ADS-500M is a desiccant dehumidifier for wind-power, grid and substation environments. Its published moisture-removal rating is 2.5 kg/h at 20 °C and 60% RH; final selection should be confirmed against the actual temperature, humidity or dew-point target, airflow, filtration, regeneration-air and installation conditions.

Dehumidification Capacity
2.5 kg/h
Process Airflow
550 m³/h
Operating Temperature
-30–+50 °C
Power Supply
AC 220V 50Hz
ADS-500M
ADS-500M — wind-power application reference Application reference

Product selection should be confirmed against temperature, target humidity, airflow, drainage, power supply, and installation conditions.

Product overview

What ADS-500M is designed to do

ADS-500M is a desiccant dehumidifier for wind-power, grid and substation environments. Its published moisture-removal rating is 2.5 kg/h at 20 °C and 60% RH; final selection should be confirmed against the actual temperature, humidity or dew-point target, airflow, filtration, regeneration-air and installation conditions.

01

2.5 kg/h rated moisture removal at 20 °C and 60% RH

02

Published operating range from -30 °C to +50 °C

03

Separate process-air and regeneration-air paths

04

G4, F7 and H11 filtration listed for both air streams

05

Dry-contact control-board interface

Technical data

Product specifications

Values below are retained from the current product record. Final configuration should be confirmed in the project quotation.

Specification Unit ADS-500M
Dehumidification Capacity (20°C/60% RH) kg/h 2.5
Operating Temperature °C -30–+50
Process Airflow m³/h 550
Regeneration Airflow m³/h 155
Rated Power W 3700
Power Supply V/Hz AC 220V 50Hz
Rated Current A 17
Process Air Filter G4 / F7 / H11
Regeneration Air Filter G4 / F7 / H11
Control Dry-contact control board
Machine Dimensions (L×W×H) mm 742 × 521 × 795
Net Weight kg 65

Application fit

Where this product can be evaluated

Application fit depends on the moisture load, operating temperature, room volume, airflow path, and installation constraints.

  1. 01Wind-power equipment
  2. 02Grid equipment
  3. 03Substations

Project support

Confirm the right configuration for your operating conditions.

Share the operating temperature, current and target humidity, room dimensions, airflow, power supply, drainage method, and installation limits. Yakeclimate can use these details to recommend a suitable next step.